Search
weiter zur Liste zurück pdf print Heavy duty connector C 146 E AV
![]() | 48932 300 V, 9 A |
| In general approvals refer to representative versions of the connector. Extent and specification of tests upon request | |
C 146 E AV Contact insert 6 + PE | ||
| Part No. | C146 12A006 102 1 | |
| Series | Heavy duty connectors C 146 | |
| Subseries | Heavy duty connector C 146 E AV | |
| Common Characteristics | ||
| No. of contacts | 6 + PE | |
| Electrical Characteristics | ||
| Rated voltage | DIN EN 60664-1 / IEC 60664-1 | 400 V (600 V UL / CSA) |
| Rated impulse voltage | DIN EN 60664-1 / IEC 60664-1 | 6000V |
| Rated current at 40°C | 22 A | |
| Voltage proof | DIN EN 60512-2, Test 4a / IEC 60512-2, Test 4a | 2.800 V |
| Installation category | DIN EN 60664-1 / IEC 60664-1 | III |
| Insulation group | DIN EN 60664-1 / IEC 60664-1 | III b |
| Insulation resistance | DIN EN 60512-2, Test 3a / IEC 60512-2, Test 3a | ≥ 1012 Ω |
| Contact resistance | DIN EN 60512-2, Test 2a / IEC 60512-2 Test 2a | < 5 mΩ |
| Clearance | DIN VDE 0627 | > 4,0 mm |
| Creepage | DIN VDE 0627 | > 6,3 mm |
| Current carrying capacity | DIN EN 60512-3, Test 5b / IEC 60512-2 Test 5b | see derating curves |
| Pollution degree | DIN EN 60664-1 / IEC 60664-1 | 3 |
| Climatical Characteristics | ||
| Climatic category | DIN EN 60068-1 / IEC 60068-1 | 40 / 125 / 21 |
| Upper temperature | + 125 °C / 1000h | |
| Lower temperatur | - 40 °C / 16h | |
| Mechanical Characteristics | ||
| IP degree of protection | DIN EN 60529 / IEC 60529 | IP00 unmated |
| Mechanical lifetime | IEC 60512-5; Test 9 a | > 500 mating cycles |
| Materials | ||
| Contacts | CuZn | |
| Insert | PC GV | |
| Colour | grey | |
| Contact plating | silver plated | |
| Further Characteristics | ||
| Flammability | UL 94 | V-0 |