Search



Search for product attributes


  

Search Assistance



Related products


Further information (PDF)


weiter zur Liste zurück pdf print Heavy duty connector heavy|mate® - C146 A

SEV
250 V, 10 A
RU
250 V, 14 A
SA
600 V, 10 A
16 A
20 A
In general approvals refer to representative versions of the connector. Extent and specification of tests upon request

heavy|mate® - C146 A Contact insert screw termination, female insert
Part No.C146 10B016 002 4
 
SeriesHeavy duty connectors heavy|mate® - C 146
SubseriesHeavy duty connector heavy|mate® - C146 A
 
Common Characteristics
No. of contacts 16 + PE 
Weight male insert 68 g
Weight female insert 73 g
Electrical Characteristics
Rated voltageDIN EN 60664-1 / IEC 60664-1 250V 
Rated impulse voltageDIN EN 60664-1 / IEC 60664-1 4000V 
Rated current at 40°C 14 A
Voltage proofDIN EN 60512-2, Test 4a / IEC 60512-2, Test 4a 2.800 V
Installation categoryDIN EN 60664-1 / IEC 60664-1 III 
Insulation groupDIN EN 60664-1 / IEC 60664-1 III b 
Insulation resistanceDIN EN 60512-2, Test 3a / IEC 60512-2, Test 3a ≥ 1012  Ω
Contact resistanceDIN EN 60512-2, Test 2a / IEC 60512-2 Test 2a ≤ 5 mΩ
Current carrying capacityDIN EN 60512-3, Test 5b / IEC 60512-2 Test 5b see derating curves 
Pollution degreeDIN EN 60664-1 / IEC 60664-1 
Climatical Characteristics
Climatic categoryDIN EN 60068-1 / IEC 60068-1 40 / 100 / 21 
Upper temperature + 100 °C / 1000 h 
Lower temperatur - 40 °C / 16 h 
Mechanical Characteristics
IP degree of protectionDIN EN 60529 / IEC 60529 IP20 mated 
Mechanical lifetimeIEC 60512-5; Test 9 a ≥ 500 mating cycles
Materials
Contacts CuZn 
Insert PBT 
Contact plating silver plated 
Further Characteristics
Termination screw 